What is a Central Unit ref. 2405 and what is it used for?

What is a Central Unit ref. 2405 and what is it used for?

* The Central Unit allows you to manage complex door-entry and MDS video door-entry installations combined with access control.

* Each Central unit can manage up to 10000 homes, 1022 users and up to 32 street door entry, video door entry, guard units or access controls.

* You can connect up to 63 central units in a FXL network. In this case only 31 panels can be connected per Central Unit.

* It incorporates the WinCom+ Management Software.

* With the capacity to manage 1000 intercommunication panels, 1000 sensors and 1000 relays.

* Local connection (USB, RS-232) or remote (IP) to the PC via the corresponding module (see accessories).

Technical Characteristics:

- 1022 users.
- 32/31 entrances depending on the system.
- Recording of the last 3,000 incidents (entries, exits, accesses denied, alerts, etc.) in memory, without needing to download the PC.
- With the option of connecting the readers with an integrated controller and without an integrated controller (via the door controller).

Programming

All programming is done with the Wincom+ software.
    • Related Articles

    • Comparison of Fermax Kits by System

      Below are some comparison tables of the kits available in their basic versions. Connectivity Can use the app to set up call forwarding. Installation Physical installation parameters. Instalation Way-Fi Plus Way-Fi See-U Way New Way Meet Duox Plus 4N ...

    Find manuals, technical books, tender specifications and much more on our professional website.

       
      Fermax International Distribution Network.