[WAY-FI PLUS] Configuration when adding or replacing a panel and/or monitors in a WAY-FI PLUS ref 1571 installation.
If in an installation of the Way-Fi Plus ref 1571 kit we need to add or replace a panel and/or monitor, we must make a record in a database that stores the MASTER panel of the installation. This means that the outdoor panels know who to call and the monitors know who to switch on automatically.
Configuration process when adding or replacing panel or monitor in an installation:
• Add
non-master panel:
-
Configure
(Dip1 and 2 OFF)
-
Wire
-
Power
up
-
Press
Reset 5’ until beep.
|
•
Add
another monitor:
-
Wiring
-
Power
-
Factory
Reset (if not new).
-
Perform
Wizard
|
• Replace
master panel:
-
Configure
(DIP1 and 2 ON)
-
Wire
-
Power
up
-
Press
Tamper 5 times <3 seconds.
|
•
Replace
monitor:
-
Wiring
-
Power
-
Factory
Reset (if not new).
-
Perform
Wizard
|