How do I add an additional monitor or board to my see-u kit?
Below you can see how we would add an additional monitor or board. It is allowed to have with the kit up to 4 cascaded monitors including the one in the kit.
The intermediate monitors will be configured like this
and will be configured in the programming menu with the different address as an EXT.
The last monitor in the cascade connection (monitor to monitor wiring) will have this configuraction.
If I add an additional board, one will be with JP2 on board 1 and the other will be with JP2 on board 2, see diagram.
Example of installation with 2 monitors in the same kit and additional board
Related Articles
[SEE-U WIFI] How to modify the opening time on a VIDEO SEE-U WIFI KIT 7” 1L REF 1393.
The VIDEO SEE-U WIFI KIT 7’ 1L REF 1393 allows us to modify the door opening time and the relay opening time (gate opening) through the monitor. To do this, we will follow the steps below: 1-. Turn on the monitor screen. Touching the screen activates ...
Which SEE-U kit models are available?
We have both the SEE-U WIFI Kit REF. 1393 and the See-u NO WIFI Kit REF. 1391 are distinguished by the monitor included in the kit. Both use the same outdoor panel and accessories but the monitor is different. WIFI Kit - WIFI Monitor ref. 1394 Kit NO ...
Is my way-fi kit or way kit compatible with the see-u?
No. They are not compatible with each other even if they seem to belong to the same product family. Only see-u devices are compatible with each other. SEE-U board with a see-u wifi and see-u non-wifi monitor can be installed in the same installation.
Can I add two analogue aerial cameras to my see-u kit?
If you only have one kit, with one outdoor panel, you will only be able to connect one aerial camera as it connects directly to the panel. If you add a second panel ref. 1395, you could also add a second ANALOG PAL camera that would be connected to ...
How do I configure an additional panel to the see-u kit?
When adding an external entrance panel ref. 1395, the additional panel must be configured at the rear using jumper JP2, setting the jumper to position 1 and 2, indicating that it will be panel 2.