[DUOX] Incompatibility ref. 3253 2S V30.30 regenerator with DUOX PLUS monitors HWxx/FW43/44/45

[DUOX] Incompatibility ref. 3253 2S V30.30 regenerator with DUOX PLUS monitors HWxx/FW43/44/45

When replacing a DUOX 3 monitor with a DUOX PLUS monitor, the call is cut off.

Details

We have detected that in DUOX installations with 2-output regenerators ref. 3253 V30.30, when replacing a DUOX 3 monitor with a DUOX PLUS HWxx-FW43/44/45 monitor, the call and video enter the monitor but we may encounter the following symptoms and solutions.

a) Symptom

When receiving a call and video, the call is cut off after 5-10 seconds, without picking up the phone.

Warning
DUOX installations with 3253 V30.30 regenerators - Incompatibility with DUOX PLUS VEO HW..FW43/44/45 monitors

Solution

If they are WIFI monitors, contact Technical Support to upgrade to version 46 or higher.

If they are NOT WIFI monitors, contact the technician in your area to report the incident and to be supplied with a monitor of the latest version. HWXX FW 46 or higher.

b) Symptom

When receiving a call and video, the call is cut either when the phone is picked up or after a few seconds. 

Alert
If video and audio are cut off when picking up the line, or after a few seconds, it may be due to a lack of power. Check the power supply.

Solution

Add power if it is below 18Vdc.



    Find manuals, technical books, tender specifications and much more on our professional website.

       
      Fermax International Distribution Network.