[CORA] Installation recommendations for areas with reflective surfaces

[CORA] Installation recommendations for areas with reflective surfaces

Recommendations on Location and Orientation:

  • Whenever possible, install the panel so it is not directly facing reflective surfaces.
  • A slight adjustment to the installation angle can help prevent unwanted activations.

Avoid installing the panel:

  • In front of or next to reflective surfaces such as marble, glass, or glazed doors.
  • Facing another CORA panel located at a short distance.
  • Inside protective enclosures with a glass front.

If environmental conditions cannot be changed:

  • Configure the panel so that the display is activated only by keypad operation.
    • To enable this option, go to the Settings > Display menu and select Activate at "Press key".

Notes
These recommendations help ensure stable display operation and prevent constant and permanent activations caused by reflections or specific environmental conditions.


    Find manuals, technical books, tender specifications and much more on our professional website.

       
      Fermax International Distribution Network.