[AC-MAX] What maximum distance can I have between the furthest reader and the controller if it is fingerprint or wiegand?
If the reader is an AC-MAX fingerprint reader ref. 5225 this reader is connected to the controller by RS-485, therefore up to 1200m, but additionally, it must be considered that it is also connected by Ethernet, therefore it will have to have a switch every 100m to reach these distances.
If it is a wiegand MIFARE reader, it can reach up to 100mts and if it is a Cityline, Skyline or MARINE EM reader it will be 10mts.
Related Articles
[ACMAX] Procedure for converting the MIFARE identifier to a decimal format compatible with ACMAX
If the screen-printed text on the card or key fob only shows FERMAX MIFARE (or does not include the ACX identifier), it is not possible to enter this code directly into AC-MAX, as the two technologies use different encryption algorithms. Registering ...
Do MIFARE 5296, 6958, 7461, 6957, 7463 or 5225 readers support Desfire cards? What about the Resistant 5293 keypads?
A Fermax proximity reader such as the Resistant 5296 (WG), Cityline 6958, or Skyline 7461 with an external controller, or the Cityline Desfire 6957, Skyline Desfire 7463, and the AC-MAX 5225 fingerprint reader also read FERMAX Desfire 4531 cards or ...